Salient Feature

1 step Blue uPVC Cement for schedule 40 to 80 uPVC piping systems up to 4”inch heavy Bodied, Medium Setting meet ASTMF-793

 

Caution!

Extremely flammable vapor harmful if swallowed, drink water. Do not induce vomiting, call a physician. If inhaled, get fresh air, If breathing problem persist seek medical attention. In case of eye and skin contact, immediately flush with plenty of water. Seek medical attention, if irritation persists.

 

Directions For Use

Recommended for uPVC Pipes upto 4”. Meets ASTM standard F-493. Store and use at temperatures between 40F and 100F. Stir or shake before using, If “jelly-like” don’t use. Square pipe ends. Remove all burrs and dirt. Clean pipe and fitting with primer. Recommended applicator for pipe over 3” is brush ½ the pipe diameter. Apply liberal coal or cement to pipe fo the depth of the socket. Apply thin coat of cement to fitting. Do not “overcoat” thin wall or bell end pipe. Assemble parts QUICLY! CEMENT MUST BF FLUID, if not fluid, re-coat both parts. Push pipe FULLY into fitting using a ¼ turning motion until pipe bottoms. Hold pipe and fitting together for 60 seconds. Allow joint to cure suffice gently before handling. Do not pressure test until cement is fully cured. Keep container closed when not in use. Do not mix any solvent.

cpvc small

SIZE

BOX

MASTER BAG

20 ml. Tube 100 600
59 ml. Tin 30 240
118 ml. Tin 24 144
237 ml. Tin 24 96
473 ml. Tin 12 48






cPVC Solvent

upvc

TECHNICAL FEATURES & CARE

1 step gold yellow cPVC Cement for Schedule 40 & 80 cPVC piping systems up to 4” inch heavy Bodied, Medium Setting meet ASTMF-793

 

Caution!

Extremely flammable vapor harmful if swallowed, drink water. Do not induce vomiting, call a physician. If inhaled, get fresh air, If breathing problem persist seek medical attention. In case of eye and skin contact, immediately flush with plenty of water. Seek medical attention, if irritation persists.

 

Directions For Use

Recommended for cPVC Pipes upto 4”. Meets ASTM standard F-493. Store and use at temperatures between 40F and 100F. Stir or shake before using, if ”jelly-like” don’t use. Square pipe ends. Remove all burrs and dirt. Clean pipe and fitting wit primer. Recommended applicator for pipe over 3” is a brush ½ the pipe diameter. Apply liberal coal or cement pipe fo the depth of the socket. Apply thin coat of cement to fitting. Do not “overcoat” thin wall or bell end pipe. Assemble parts AUICKLY! CEMENT MUST BF FLUID,if not fluid, re-coat both parts. Push pipe FULLY into fitting using a 1/4 turning motion until pipe bottoms. Hold pipe and fitting together for 60 seconds. Allow joint to cure suffice gently before handling. Do not pressure test until cement is fully cured. Keep container closed when not in use. Do not mix any solvent.

upvc small

SIZE

BOX

MASTER BAG

59 ml. 40 160
118 ml 24 96
237 ml 12 48
473 ml 6 24